Table 1:

Materials properties (mean±std) obtained from micropillar compression, nanoscratch, and tissue tensile tests for wild type and oim/oim bone samples.

Test modes Material property wild type oim/oim p-value
Micropillar test Compression work to fracture [MJ/m3] 13.9±2.7 8.2±0.9 <0.05
Elastic modulus [GPa] 24±6.8 21±3.1 >0.05
Ultimate stress [MPa] 584±157 521±104 >0.05
Tensile test Ultimate stress [MPa] 50±4.5 38±5.3 <0.001