Skip to main content
. 2020 Mar 26;27(4):269–273. doi: 10.1097/SPV.0000000000000807

TABLE 2.

Three-dimensional Ultrasound Examination of Intervention (I and II) and Control (III) Groups

PFM Integrity LH-AD, Mean (SD), mm LH-LD, Mean (SD), mm HA, Mean (SD), cm2
Before After Before After Before After
Group I 51.10 (6.80)† 47.98 (6.25)* 41.44 (6.43)† 38.40 (6.03)* 14.47 (1.72)† 13.09 (1.78)*
Group II 52.52 (5.75)† 51.36 (5.36)† 46.60 (6.70)† 45.56 (6.41)† 14.77 (1.82)† 14.69 (1.79)†
Group III 46.60 (2.30) N/A 35.40 (2.50) N/A 11.59 (0.35) N/A

Data are expressed as mean with SD. Group III was measured only at the baseline as a reference, therefore values after treatment are not available.

*Statistically significant differences against baseline (P < 0.05).

†Statistically significant differences against control.

N/A, not available.