Table 2.
The experimental data of KTZ solubility in SC-CO2 based on distinct conditions (The experimental standard deviation and the experimental standard deviation of the mean (SD) were obtained by and respectively.
| Temperaturea (K) | Pressurea (MPa) | Densityb (kg/m3) | Binary | ||||
|---|---|---|---|---|---|---|---|
| y2 × 105 (Mole Fraction ) | Standard deviation of the mean, SD(ȳ) × (105) | Expanded uncertainty of mole fraction (105 U) | S (Solubility (g/l)) | ||||
| 308 | 12 | 768.42 | 0.17 | 0.001 | 0.008 | 0.016 | |
| 15 | 816.06 | 0.34 | 0.003 | 0.016 | 0.034 | ||
| 18 | 848.87 | 0.44 | 0.017 | 0.039 | 0.045 | ||
| 21 | 874.4 | 0.62 | 0.017 | 0.044 | 0.066 | ||
| 24 | 895.54 | 0.80 | 0.034 | 0.077 | 0.087 | ||
| 27 | 913.69 | 0.94 | 0.017 | 0.054 | 0.104 | ||
| 30 | 929.68 | 1.09 | 0.051 | 0.114 | 0.122 | ||
| 318 | 12 | 659.73 | 0.07 | 0.003 | 0.007 | 0.006 | |
| 15 | 743.17 | 0.32 | 0.010 | 0.027 | 0.036 | ||
| 18 | 790.18 | 0.85 | 0.034 | 0.079 | 0.081 | ||
| 21 | 823.7 | 1.31 | 0.035 | 0.090 | 0.130 | ||
| 24 | 850.1 | 1.68 | 0.069 | 0.157 | 0.173 | ||
| 27 | 872.04 | 2.11 | 0.035 | 0.115 | 0.222 | ||
| 30 | 890.92 | 2.59 | 0.086 | 0.207 | 0.279 | ||
| 328 | 12 | 506.85 | 0.04 | 0.001 | 0.003 | 0.003 | |
| 15 | 654.94 | 0.30 | 0.002 | 0.015 | 0.026 | ||
| 18 | 724.13 | 0.98 | 0.035 | 0.082 | 0.086 | ||
| 21 | 768.74 | 1.82 | 0.052 | 0.131 | 0.169 | ||
| 24 | 801.92 | 2.76 | 0.050 | 0.160 | 0.267 | ||
| 27 | 828.51 | 4.02 | 0.087 | 0.247 | 0.402 | ||
| 30 | 850.83 | 4.81 | 0.068 | 0.252 | 0.494 | ||
| 338 | 12 | 384.17 | 0.02 | 0.0006 | 0.001 | 0.001 | |
| 15 | 555.23 | 0.22 | 0.010 | 0.023 | 0.015 | ||
| 18 | 651.18 | 0.90 | 0.017 | 0.056 | 0.077 | ||
| 21 | 709.69 | 2.29 | 0.052 | 0.145 | 0.196 | ||
| 24 | 751.17 | 4.2 | 0.032 | 0.198 | 0.381 | ||
| 27 | 783.29 | 6.02 | 0.085 | 0.316 | 0.569 | ||
| 30 | 809.58 | 8.02 | 0.121 | 0.427 | 0.784 | ||
n is the number of times each experimental data was measured (n = 3, in this work). Expanded uncertainty is U = k* ucombined and the relative combined standard uncertainty is defined as ucombined / y = in which u(xi)/xi is the relative standard uncertainty of each input estimate (xi) and Pi is known positive or negative number having negligible uncertainties. y2 and S are mole fraction of solute in binary system and solubility of solute in SC-CO2, respectively.
aStandard uncertainty u are u(T) = 0.1 K; u(p) = 1 bar. Also, the relative standard uncertainties are obtained below 0.05 for mole fractions and solubilities. The value of the coverage factor k = 2 was chosen on the basis of the level of confidence of approximately 95 percent.
bData from the Span–Wagner equation of state62.