Skip to main content
. 2021 Apr 7;11:55. doi: 10.1186/s13613-021-00848-y

Table 3.

Correlations of changes in MFI and PPV of small vessels with changes in hemodynamic parameters during the first RIC procedure

Variable dMFIs p dPPVs p
dMAP 0.08 0.698 − 0.30 0.874
dHR − 0.20 0.326 − 0.20 0.334
dCI 0.79 0.004 0.49 0.125
dScvO2 0.01 0.999 − 0.10 0.626
dLactate 0.06 0.784 − 0.38 0.854

The Spearman correlation coefficient was presented. dMFIs changes in microvascular flow index of small vessels, dPPVs changes in the proportion of perfused small vessels, dMAP changes in mean arterial pressure, dHR changes in heart rate, dCI changes in cardiac index, dScvO2 changes in central venous oxygen saturation, dLactate changes in arterial lactate