Skip to main content
. 2021 Jul;2(7):e311–e319. doi: 10.1016/S2666-5247(21)00056-2

Table 1.

Number of positive antigen point-of-care tests of serial dilutions of SARS-CoV-2 N and SARS-CoV-2 cell culture supernatant (triplicates)

Abbott RapiGEN Healgen Coris BioConcept R-Biopharm nal von minden Roche-SD Biosensor
SARS-CoV-2 N concentration, ng/mL
1000 3 3 3 3 3 3 3
250 3 3 3 3 3 3 3
50 3 0 3 3 3 3 3
25 3 0 3 3 3 3 3
10 3 0 3 0 3 3 3
5 2 0 3 0 3 2 3
2·5 0 0 3 0 3 0 0
SARS-CoV-2, plaque-forming unit per mL
8800 3 3 3 3 3 3 3
880 3 2 3 3 3 3 3
88 3 0 3 0 3 1 3
8·8 0 0 0 0 0 0 0
0·88 0 0 0 0 0 0 0