Table 1.

Baseline characteristics

Total patients (N = 25) Partial septal LGE (n = 10) Full-length septal LGE (n = 15) P value
Age (yr) 64 ± 8 66 ± 7 63 ± 9 .38
Male 23 (92) 9 (90) 15 (100) .21
LVEF (%) 39 (24–47) 43 (35–51) 30 (22–45) .19
Intrinsic QRS width (ms) 133 (113–188) 114 (108–133) 156(123–210) .071
Coronary artery disease 4(16) 3(30) 1(7) .27
Hypertension 10 (40) 4 (40) 6(40) 1
Diabetes mellitus 7(28) 3(30) 4(27) 1
Atrial fibrillation 11 (44) 3(30) 8(53) .41
Cardiac device
 ICD 14 (56) 7(70) 7(47) .41
 CRT-D 10 (40) 2 (20) 8(53) .21
VT storm 8(32) 2 (20) 6(40) .4
Amiodarone use 20 (80) 6 (60) 14 (93) .12
Other antiarrhythmics use 12 (48) 4 (40) 8(53) .69
Beta-blocker use 23 (92) 9 (90) 14 (93) 1
Aortic valve surgery 2(8) 0(0) 2(14) .5
Previous VT ablation 12 (48) 4 (40) 8(53) .69
 3 3(12) 1(10) 2(13)
 2 3(12) 1(10) 2(13)
 1 6(24) 2 (20) 4(27)
 0 13 (52) 6 (60) 7(47)
Clinical VT
 Right bundle branch block 12 (48) 4(40) 8(53) .69
 Inferior axis 18 (72) 7(70) 11 (73) 1
 Left axis 12 (48) 6 (60) 6(40) .43
Epicardial access 9(36) 3(30) 6(40) .69

Values are given as n (%), mean ± SD, or median (interquartile range) unless otherwise indicated.