Skip to main content
. 2014 Jun 24;16(7):524–529. doi: 10.1111/jch.12352

Table 1.

Administration of the NO‐Donating Lozenge on Vascular Compliance and Reduced Central Pressure After 30 Minutes

Baseline After NO Lozenge P Value
Mean arterial pressure, mm Hg 114±3 108±3 .003
Heart rate, beats per min 77.4±2.4 76.2±2.0 .26
Pulse pressure, mm Hg 44±3 38±2 .007
Central systolic BP, mm Hg 127±3 122±3 .01
Central diastolic BP, mm Hg 95±2 94±3 .25
Central pulse pressure, mm Hg 31.4±1.9 28.7±1.6 .07
Cardiac output, L/min 5.4±0.2 5.1±0.2 .07
Total vascular resistance, s*mm Hg/mL 1.3±0.03 1.3±0.03 .65
Augmentation pressure, mm Hg 6.2±0.8 4.3±0.6 .02
Augmentation index @75 21.2±2.5 15.4±1.7 .01
Pulse wave velocity, m/s 8.6±0.4 8.3±0.4 .005

Abbreviations: BP, blood pressure; NO, nitric oxide. Data are expressed as the average of 20 patients at baseline and a half hour after a single lozenge.