Skip to main content
. 2021 Apr 8;11:7702. doi: 10.1038/s41598-021-87295-8

Table 1.

Comparison of RLN ELISA (optical density; OD) and RT-QuIC results with ear (area 7) IOME-RT-QuIC results.

Sample ID#,* CWD status** OD RLN RT-QuIC*** EAR RT-QuIC***
3681 Positive 3.999 4/4 4/4
3806w Positive 3.999 4/4 4/4
5685w Positive 0.490 2/4 1/4 and 1/4
7424 Positive 3.999 4/4 1/4 and 4/4
0482 Positive 0.389 4/4 4/4
0504 Not detected 0/4 0/4
0902 Not detected 0/4 0/4
0913 Not detected 0/4 0/4
0924 Not detected 0/4 0/4
1042**** Positive 0.689 4/4 4/4
1403 Not detected 0/4 0/4
2136 Positive 0.372 4/4 4/4
3422w Positive 0.315 4/4 3/4 and 4/4
0262**** Not detected 0/4 0/4
0623 Not detected 0/4 0/4
0881 Not detected 0/4 0/4
0903 Not detected 0/4 2/4 and 2/4
1010 Not detected 0/4 0/4
1194 Positive 2.468 4/4 4/4
1356 Not detected 0/4 0/4
1894 Not detected 0/4 0/4
1920 Not detected 0/4 0/4
1953 Not detected 0/4 1/4 and 3/4
2546 Not detected 0/4 1/4 and 1/4
2550 Not detected 0/4 0/4
2561 Not detected 0/4 0/4
2594 Not detected 0/4 0/4
2616 Not detected 0/4 0/4
2863 Not detected 0/4 0/4
2922 Not detected 0/4 0/4
3353 Positive 1.252 4/4 0/4
3386 Positive 3.999 4/4 4/4
3482 Not detected 0/4 0/4
3493 Positive 3.999 4/4 3/4 and 4/4
3810w Positive 3.999 4/4 0/4
4624 Not detected 0/4 3/4 and 1/4
4716 Positive 2.137 4/4 4/4
4720 Positive 3.999 4/4 4/4
4753 Positive 3.999 4/4 4/4
5630 Positive 1.565 4/4 4/4
5652 Not detected 0/4 0/4
5755 Not detected 0/4 0/4
5770 Not detected 0/4 0/4
5781 Not detected 0/4 0/4
5803 Positive 0.539 4/4 1/4 and 3/4
5851 Positive 3.999 4/4 2/4 and 4/4
7376 Positive 2.371 4/4 2/4 and 2/4
7472w Not detected 0/4 0/4
7542 Positive 3.999 4/4 4/4
7995 Not detected 0/4 0/4
8264 Not detected 0/4 0/4
8360 Positive 3.999 4/4 4/4
0390w Positive 0.453 4/4 4/4
0456 Not detected 0/4 0/4
2556 Not detected 0/4 0/4
2582 Positive 0.604 4/4 0/4
3385 Positive 0.373 4/4 0/4
5285 Positive 3.333 4/4 4/4

*Sample numbers with a “w” suffix were from white-tailed deer; all others were from mule deer.

**Based on RLN ELISA and RT-QuIC results in 3rd and 4th columns, which were 100% concordant.

***Positive/total replicate reactions. Two fractions for the same sample indicate results from repeated assays in quadruplicate.

****Carcass submitted for diagnostic examination. Samples not marked came from apparently healthy hunter-killed deer.