Table 2.

Selected published articles that detected and characterised various solid materials. MUT, Material Under Test; IDC, Interdigital Capacitor; CSRR, Complementary Split Ring Resonator.

Ref. Technique Substrate Material * Freq (GHz) Size (mm) Tested Material (MUT) Remark
[39] Splitter/combiner microstrip with IDCs and 2 CSRR structures Fabricated on Rogers5880 ϵr = 2.20 h = 1 mm t = 0.018 mm 5.6 N/A Viz, PVC, glass epoxy, FR4, glass The measured complex permittivity of the test specimens is found to be in close agreement with their values available in the literature with a maximum error of ≤5%. Disadvantages: Low electric field distribution (2.667 × 103) v/m
[33] Metamaterial SRR Fabricated on FR4glass epoxy board ϵr = 3.583 h = 1.5 mm 3.57 8 × 8 Calibration: plastic, Perspex, glass epoxy, glass Extracted: Rice flour, wheat flour, all-purpose flour, corn flour, green gram flour, gram flour, soya flour Advantages:
  • -

    Potential application in the field of food preservation and quality checking

  • -

    Detecting real permittivity

Disadvantage:
  • -

    Low permittivity detection

  • -

    Low accuracy

  • -

    No weighing of flour samples

  • -

    Loss tangent not determined

[34] SRR Fabricated on RT/duroid 6006 h = 1.27-mm 2.5 80 × 40 Viz, Teflon, polyvinyl chloride, Plexiglas, polyethylene, carbonyl iron, Ni0.6Co0.4Fe2O4, cobalt, 30% polystyrene composite The measured relative permeability and the relative permittivity of the test specimens are found to be in close agreement with their values available in literature with a maximum error of less than 8%.
[46] Two spiral inductors and IDC Fabricated on FR4 h = 1.6 mm 2.2–2.8 44 × 24 Magnetic, soft cobalt steel (SAE 1018), ferrite core rubber, plastic, wood, white marble Experimentally, it is found that complex permeability and permittivity measurement is possible with an average error of 2%.
[178] A modified ring resonator Fabricated on RT/duroid 5880 ϵr = 2.2 h = 1.58 mm tanδ = 0.001 3.2 28 × 4 Peat soil, sand soil The model has within a 5% error in dielectric estimation with the commercial dielectric probe for peat soil (≥28% m.c.) and sand soil (≥10% m.c.).
[38] A metamaterial planar sensor Fabricated on FR4 h = 0.8 mm 5.3–8.2 30 × 30 Benzene, ethyl acetate, hexane, N-pentane, polyethylene, PVC, Teflon, THF For solid and hazardous liquid samples. Disadvantages:
  • -

    Limited permittivity detection from 1 to 10 real permittivity.

[25] Microstrip ring resonator Fabricated on Roger5880 ϵr = 2.2 h = 787 um tanδ = 0.0009 t = 17.5 um 1 141 × 87.5 Air, meat The maximum discrepancy is about 6% only. Disadvantages:
  • -

    Simulated and measured results have a discrepancy, which is observed for the loss magnitude (around 15%).

* h = thickness, t = copper thickness, ϵr = dielectric constant, and tanδ = loss tangent. N/A = Not Available.