Skip to main content
. 2021 Mar 30;13(7):1086. doi: 10.3390/polym13071086

Table 2.

SFV1enh/Luc recombinant virus titer change after pressure filtration through experimental materials (KF = Kraft fibers; HF = hemp fibers; FF = fungal fibers; Ga = G. applanatum; Tv = T. versicolor).

Sample Virus Titer
i.u./mL ± SD
Virus Titer
[Log10]
Log10 Reduction Value
LRV
Virus Amount after Filtration Relative to Nonfiltered Control
%
Non-filtered virus (1 ± 0.066) × 107 7.00 - 100
Surgical mask (all layers) (8.28 ± 0.066) × 106 6.92 0.08 92.63
Cellulose hygienic paper (2.66 ± 0.076) × 106 6.42 0.58 27.05
KF (1.43 ± 0.413) × 104 4.16 2.84 0.16
KF FF (Ga) (2.86 ± 0.076) × 102 2.46 4.54 0.00
KF FF (Tv) (7.66 ± 0.791) × 104 4.88 2.12 0.78
FF (Ga) (2.25 ± 1.460) × 104 4.35 2.65 0.26
HF (6.27 ± 2.120) × 103 3.80 3.20 0.08
Cotton outer layer
(hydrophobic)
(7.21 ± 0.0330) × 106 6.86 0.14 73.44
Cotton Silverplus middle layer (2.52 ± 3.350) × 103 3.40 3.60 0.03
Cotton inner layer (7.31 ± 1.300) × 105 5.86 1.14 7.44