Skip to main content
. 2021 Mar 30;21(7):2389. doi: 10.3390/s21072389

Table 3.

Geometric dimensions of the experimentally determined measuring ranges of all applied measuring systems.

Sensor Sphere Coverage Bounding Box / mm Volume /
Arel Aabs BBX BBY BBZ mm3
ATOS Compact Scan 2M MR 2 0.9 3.28 ×101 193.48 174.93 175.09 4.98 ×106
0.8 2.92 ×101 200.19 187.65 181.61 5.65 ×106
0.7 2.55 ×101 205.79 195.07 182.70 5.94 ×106
ATOS Core 200 5M 0.9 2.10 ×101 136.34 188.74 93.68 1.43 ×106
0.8 1.87 ×101 158.77 195.37 128.00 2.68 ×106
0.7 1.64 ×101 160.50 199.78 131.58 2.94 ×106
ATOS Compact Scan 2M MR 1 0.9 3.40 ×101 72.75 97.89 84.83 4.71 ×105
0.8 3.02 ×101 80.26 104.42 94.87 6.04 ×105
0.7 2.65 ×101 83.54 107.98 96.37 6.56 ×105
TR 73 Endo 20 0.9 3.12 ×102 13.96 11.39 4.47 2.96 ×102
0.8 2.77 ×102 18.42 16.86 6.81 1.08 ×103
0.7 2.43 ×102 19.88 18.98 7.87 1.50 ×103
LMI/GFM MikroCad pico 0.9 4.92 ×102 7.96 10.45 2.46 8.77 ×101
0.8 4.37 ×102 10.89 14.49 4.29 3.25 ×102
0.7 3.82 ×102 11.64 18.05 4.84 4.92 ×102
TR 73 Endo 10 0.9 3.44 ×103 8.32 6.88 2.57 3.87 ×101
0.8 3.06 ×103 13.73 12.30 3.55 2.07 ×102
0.7 2.68 ×103 16.54 17.83 4.53 5.05 ×102