Skip to main content
. 2021 Apr 3;21(7):2496. doi: 10.3390/s21072496

Table 3.

Mean ± standard deviation and coefficient of variation (in brackets) of RF classifiers performance metrics in test dataset for predicting imminent birth (TTD ≤ 7days) in women with threatened preterm labor (TPL) using EHG data or a combination of EHG and obstetric data. The maximum value for each metric is shown in bold. F1: F1-score, Sens: Sensitivity, Spec: Specificity.

Opt. Criterion Inputs Classifier Test_F1 Test_Sens Test_Spec
F1-Score
Sensitivity
EHGP10–P90 + Obs RFF1_1 77.51 ± 7.58% (9.8%) 66.22 ± 11.70% (17.7%) 97.12 ± 4.13% (4.3%)
EHGP50 + Obs RFF1_2 80.35 ± 6.78% (8.4%) 74.00 ± 10.41% (14.1%) 92.25 ± 5.35% (5.8%)
EHGP10–P90 RFF1_3 77.81 ± 8.71% (11.2%) 65.78 ± 11.61% (17.6%) 98.29 ± 2.51% (2.6%)
EHGP50 RFF1_4 77.7 ± 6.6% (8.5%) 71.44 ± 10.99% (15.4%) 90.72 ± 4.58% (5.0%)