Skip to main content
. 2021 Apr 3;21(7):2496. doi: 10.3390/s21072496

Table 4.

Mean ± standard deviation and coefficient of variation (in brackets) of ELM classifiers’ performance metrics in test dataset for predicting imminent birth (TTD ≤ 7 days) in women with TPL using EHG data or a combination of EHG and obstetric data. The maximum value for each metric and optimization criterion is shown in bold. F1: F1-score, Sens: sensitivity, Spec: specificity.

Opt. Criterion Inputs Classifier Test_F1 Test_Sens Test_Spec
F1-score EHGP10–P90 + Obs ELMF1_1 80.00 ± 4.98% (6.0%) 87.56 ± 8.53% (9.7%) 74.77 ± 7.32% (9.8%)
EHGP50 + Obs ELMF1_2 82.14 ± 5.88% (7.2%) 89.89 ± 7.14% (7.9%) 76.40 ± 8.12% (10.6%)
EHGP10–P90 ELMF1_3 78.41 ± 4.55% (5.8%) 85.89 ± 7.91% (9.2%) 73.24 ± 6.93% (9.5%)
EHGP50 ELMF1_4 79.00 ± 5.06% (6.4%) 86.22 ± 6.65% (7.7%) 73.87 ± 8.64% (11.7%)
Sensitivity EHGP10–P90 + Obs ELMSEN_1 74.83 ± 3.88% (5.2%) 95.44 ± 4.59% (4.8%) 51.35 ± 9.28% (18.1%)
EHGP50 + Obs ELMSEN_2 75.42 ± 3.96% (5.3%) 96.00 ± 5.13% (5.3%) 52.25 ± 9.58% (18.3%)
EHGP10–P90 ELMSEN_3 73.13 ± 3.10% (4.2%) 94.78 ± 4.61% (4.9%) 47.57 ± 8.83% (18.6%)
EHGP50 ELMSEN_4 73.83 ± 3.24% (4.4%) 94.89 ± 5.01% (5.3%) 49.37 ± 9.63% (19.5%)