Table 3.
Compounds | Concentration (μg/mL) | Intra-Day (n = 3) | Inter-Day (n = 3) | ||||
---|---|---|---|---|---|---|---|
Mean ± SD | RSD (%) | Accuracy | Mean ± SD | RSD (%) | Accuracy | ||
G-Re | 25 | 23.41 ± 0.58 | 2.50 | 93.6 | 24.03 ± 0.22 | 0.92 | 96.1 |
125 | 128.56 ± 2.92 | 2.27 | 102.8 | 126.88 ± 1.46 | 1.15 | 101.5 | |
250 | 252.11 ± 1.42 | 1.16 | 100.8 | 249.08 ± 0.29 | 0.12 | 99.6 | |
25 | 24.69 ± 0.58 | 2.37 | 98.8 | 25.06 ± 0.22 | 0.88 | 100.2 | |
G-Ra8 | 125 | 136.61 ± 1.21 | 0.96 | 101.3 | 126.24 ± 1.46 | 1.16 | 101.0 |
250 | 228.33 ± 1.20 | 0.52 | 91.3 | 224.16 ± 0.29 | 0.13 | 89.7 | |
25 | 27.43 ± 0.27 | 1.23 | 109.7 | 27.49 ± 0.07 | 0.24 | 110.0 | |
G-Rf | 125 | 127.33 ± 2.01 | 0.59 | 101.9 | 128.65 ± 0.76 | 0.56 | 102.9 |
250 | 272.09 ± 4.75 | 1.75 | 108.8 | 265.50 ± 3.49 | 1.31 | 106.2 |
Photo diode array detector method for the determination of G-Re, G-Ra8, and G-Rf (n = 3). RSD, relative standard deviation.