Skip to main content
letter
. 2021 Apr 12;56(8):2013–2015. doi: 10.1038/s41409-020-01208-3

Fig. 1. CD34+ cell recovery and viability, CD45+ cell viability and potency assay assessment of HPC grafts of both RD and URD after thawing and washing.

Fig. 1

Single-platform flow cytometry-based analysis was used for viable CD34+ and CD45+ cells enumeration and measurement of viability, while a 14-day culture and automated cell counting were performed to report CFU counts and clonogenicity. CD34+ cell recovery was calculated as the ratio of absolute count of post-wash viable CD34+ cells to pre-cryopreservation absolute counts of viable CD34+ cells. Clonogenicity was calculated as the percentage of CFU count (×104) to post-wash viable CD34+ cells absolute count (×106). Data are presented as median ± interquartile ranges. Recovery, viabilities and clonogenicity are reported as percentages using the left y-axis. CFU is reported as count (×104/kg) using the right y-axis. Open symbols represent RD, closed symbols represent URD. p values are reported above the groups using Mann–Whitney test for null hypothesis testing.