Fault mode and fault value of four-op-amp biquad highpass filter circuit.

Fault mode Fault class Normal value Fault value
F0 Normal
F1 C1↑ 5 nF 10 nF
F2 C1↓ 5 nF 2.5 nF
F3 C2↑ 5 nF 15 nF
F4 C2↓ 5 nF 2.5 nF
F5 R1↑ 6.2 KΩ 15 kΩ
F6 R1↓ 6.2  kΩ 3  kΩ
F7 R2↑ 6.2  kΩ 18  kΩ
F8 R2↓ 6.2  kΩ 2  kΩ
F9 R3↑ 6.2  kΩ 12  kΩ
F10 R3↓ 6.2  kΩ 27  kΩ
F11 R4↑ 1.6  kΩ 25  kΩ
F12 R4↓ 1.6  kΩ 500 Ω