Table 3. The relative performance of serological tests against a combination of statutory ante-mortem and post-mortem diagnostic techniques.
Test type | n | Comparator | P-value | AUC | Sens | Spec | PPV | NPV | Prev. (comparator) | Test prev. |
---|---|---|---|---|---|---|---|---|---|---|
ENFER 2ag | 187 | SICCT + VL + CONFIRM | 0.019 | 0.54 | 9.09% | 99.30% | 80.00% | 78.02% | 24% | 2.67% |
ENFER 4ag | 187 | SICCT + VL + CONFIRM | 0.045 | 0.53 | 6.82% | 99.30% | 75.00% | 77.60% | 24% | 2.14% |