Table 13.
Best STP6-120/36, PV (STE 4/100) and Leybold solar (LEYBOLD 664431) modules results.
| Photovoltaics module | Algorithms | Best parameters |
Best RMSE | ||||
|---|---|---|---|---|---|---|---|
| Iph(A) | Io(μA) | n | Rs(Ω) | Rp(Ω) | |||
| STPE6-120/36 | DSO | 7,4752 | 1,9308 | 1,2818 | 0,004691 | 15.83880 | 1.42510 × 10−2 |
| MADE [36] | 7,4725 | 2.335 | 1.2601 | 0.0046 | 22.2199 | 1.6601 × 10−2 | |
| ITBLO | 7.4725 | 2.3350 | 1.2601 | 0.0046 | 22.2199 | 1.6601 × 10−2 | |
| IJAYA | 7.4672 | 2.2536 | 1.2571 | 0.0046 | 27.5925 | 1.6731 × 10−2 | |
| STBLO | 1.1679 | 7.4814 | 1.2048 | 0.0055 | 9.8 | 1.6211 × 10−2 | |
| LEYBOLD 664 431 | DSO | 0.1540 | 1.228x10−2 | 1.3865 | 5.1552 | 2202.828 | 3349651 × 10−4 |
| Brent [63] | NA | NA | NA | NA | NA | 8.3838 × 10−4 | |
| STE 4/100 | DSO | 0.0264 | 2.011x10−3 | 1.2015 | 1.4787 | 2128.8 | 2.9852 × 10−4 |
| Brent [63] | NA | NA | NA | NA | NA | 3.339 × 10−4 | |