Table 3.

The sensitivity of MADT for different ACL injuries

Item Subgroup (number) Number of positive of MADT (sensitivity) χ2, p value
ACL ruptures Acute (53) 44 (0.83) χ2 = 1.682, p = 0.195
Nonacute (95) 87 (0.92)
Partial ACL ruptures AM bundle (8) 6 (0.75) p = 0.130 (Fisher test)
PL bundle (14) 6 (0.43)