Skip to main content
. 2021 Apr 15;133:104375. doi: 10.1016/j.compbiomed.2021.104375

Table 10.

Comparing CovidXrayNet with Benchmark. All models are based on three-class COVID-19 classification. COVID-Net and CovidXrayNet employed the COVIDx dataset.

Model Acc (%) MCC (%) Precision (%) Recall (%) F1 (%)
DarkCovidNet [24] 87.02 _ 89.96 _ 87.37
COVID-Net [20] 93.30 _ _ _ _
MobileNet v2 [26] 93.48 _ _ _ _
CovidXrayNet 95.82 92.24 96.93 95.43 96.16