Skip to main content
. 2020 Oct 20;27(2):172–180. doi: 10.1177/1591019920968370

Table 2.

A table showing the demographics, radiological characteristics of the initial and the recurrent aneurysms that did not meet the criteria of “early major recurrence” and their management.

Patient Number Gender Age (years) Location Rupture status Maximal diameter(mm) Height (mm) Neck (mm) Height/Neck ration RRS Recurrence detection (months) Maximal diameter (mm) Height (mm) Re-treatment
1 F 40 Acom R 3 2 2 1 2 6 1 2 None
2 M 51 Paraopthalmic R 13 12 7 1.7 2 42* 16** 10 FD
3 F 61 Acom R 4.5 3 2.5 1.2 1 6 2 2 BAC
4 F 62 Basilar U 11 7 4 1.75 1 5 4 4 SAC
5 F 62 Paraopthalmic R 23 14 4.5 3.1 2 6 19 9 FD
6 F 62 Pcom R 4 3 3 1 2 6 4 3 SAC
7 F 81 AICA U 7 5 4 1.25 1 96 * 8** 6 Coil
8 F 52 SHA R 10 8 4 2 2 6 5 4 SAC
9 F 31 Ophtalmic R 6 3 3 1 2 6 3 3 SAC
10 F 45 Ophtalmic R 10 5 3.5 1.4 1 12 4.5 2.5 FD
11 F 56 Pcom R 9 7 3 2.3 1 6 4 3 Coil
12 F 60 Basilar U 14 12 8 1.5 1 6 6 4 Coil
13 F 50 Pcom U 4 4 3 1.3 1 12 2 2 None
14 F 35 Pcom R 8 7 3 2.3 1 12 3 2 None
15 F 55 Pcom R 7.2 4.7 4 1.2 2 6 4 3 BAC
16 M 52 Basilar R 8 8 6 1.3 1 18 6 4 SAC
17 F 26 Cavernous R 22 19 10 1.9 2 24* 8 6 FD
18 F 45 Pcom R 5 3 2.5 1.2 2 6 3 2 BAC
19 F 70 Ophtlamic R 6 5 4 1.25 2 6 4 3 BAC

Abbreviations: Acom: Anterior communicating aneurysm; Pcom: posterior communicating aneurysm; AICA: anterior inferior cerebellar artery; SHA: superior hypophyseal artery; R: ruptured; U: unruptured; RRS: Raymond-Roy Scale; FD: flow diversion; SAC: stent-assisted coiling; BAC: balloon assisted coiling; Coil: coiling.

*Recurrence detected at later follow up.

**Recurrence larger than the initial size but detected at a later follow-up.