Skip to main content
. 2021 Mar 23;7(2):e71. doi: 10.1192/bjo.2021.31

Table 2.

ECT treatment characteristics

Low-dose interval, n = 3455 Medium-dose interval, n = 2430 High-dose interval, n = 2032 P-value
Mean (s.d.) or n (%) Mean (s.d.) or n (%) Mean (s.d.) or n (%)
Number of sessions in series 7.5 (3.5) 7.8 (3.4) 8.1 (3.3) <0.001
Charge (mC) 401.7 (186.8) 407.8 (186.6) 407.7 (181.1) 0.353
Seizure duration(s) 38.7 (16.1) 37.1 (16) 36.0 (33.2) <0.001
Electrode placement 0.863
Unilateral 3069 (89.5%) 2160 (89.6%) 1800 (89.1%)
Bitemporal 279 (8.1%) 199 (8.3%) 178 (8.8%)
Bifrontal 82 (2.4%) 52 (2.2%) 43 (2.1%)

The table shows treatment characteristics for the ECT series of each group, including the total number of sessions in the series, charge given for the last treatment in each series, seizure duration for the last treatment in the series and electrode placement. P-values were calculated using one-way ANOVA for mean and Pearson chi-square for proportions. ECT, electroconvulsive therapy; mC, millicoulomb.