Table 4. Sensitivity, specificity, negative and positive predictive values for small and diminutive polyps according to optical diagnosis. 1 .
SIMPLE diagnosis | Accuracy of optical diagnosis, n/N (%) [95 %CI] | ||||
Sensitivity | Specificity | NPV | PPV | Rectosigmoid NPV 2 | |
Diminutive polyps | |||||
|
98/126 (77.8) [69.5–84.7] | 76/125 (60.8) [51.7–69.4] | 76/104 (73.1) [63.5–81.3] | 98/147 (66.7) [58.4–74.2] | – |
|
66/120 (55.0) [45.7–64.1] | 121/131 (92.4) [86.4–96.3] | 121/175 (69.1) [61.7–75.9] | 66/76 (86.8) [77.1–93.5] | 72/83 (86.7) [77.5–93.2] |
|
2/5 (40.0) [0.5–85.3] | 220/246 (89.4) [84.9–93.0] | 220/223 (98.7) [96.1–99.7] | 2/28 (7.1) [0.9–23.5] | – |
Small polyps | |||||
|
107/144 (74.3) [66.3–81.2] | 118/173 (68.2) [60.7–75.1] | 118/155 (76.1) [68.6–82.6] | 107/162 (66.0) [58.2–73.3] | – |
|
91/161 (56.5) [48.5–64.3] | 145/156 (92.9) [87.7–96.4] | 145/215 (67.4) [60.7–73.7] | 91/102 (89.2) [81.5–94.5] | 80/94 (85.1) [76.3–91.6] |
|
8/12 (66.7) [34.9–90.1] | 260/305 (85.2) [80.8–89.0] | 260/264 (98.5) [96.2–99.6] | 8/53 (15.1) [6.7–27.6] | – |
NPV, negative predictive value; PPV, positive predictive value.
For high-confidence diagnoses.
Adenomas and sessile serrated adenomas were considered to be equivalent.