. 2021 Jan 26;9(3):655–664. doi: 10.1007/s43390-020-00275-2

Table 3.

Simulated post-op. values of 3D descriptors (MT Cobb, TK and MT AVR) for each of ten thoracic cases and for each simulated screw pattern

Patient 3D descriptor (°) Screw pattern / ID Avg ± SD [min; max] max–min
A / 1.2 PAD / 1.4 CA / 1.6 CPAD /1.7 B / 2
#1 MT Cobb 24 24 23 22 22 23 ± 1 [22; 24] 1.9
TK 17 17 18 18 18 18 ± 0 [17; 18] 1.0
AVR 1 1 1 1 1 1 ± 0 [1; 1] 0.4
#2 MT Cobb 22 22 19 19 20 20 ± 2 [19; 22] 3.8*
TK 33 31 32 32 32 32 ± 0 [31; 33] 1.3
AVR − 3 1 − 1 0 0 − 1 ± 1 [− 3; 1] 3.8*
#3 MT Cobb 18 17 16 16 15 16 ± 1 [15; 18] 2.7
TK 19 19 20 19 19 19 ± 0 [19; 20] 1.3
AVR − 5 − 1 − 2 − 1 − 1 − 2 ± 2 [− 5; − 1] 3.9*
#4 MT Cobb 19 18 17 17 17 18 ± 1 [17; 19] 2.7
TK 18 15 17 17 17 17 ± 1 [15; 18] 3.2*
AVR − 11 − 10 − 11 − 10 − 11 − 11 ± 1 [− 11; − 10] 1.3
#5 MT Cobb 28 29 27 26 27 27 ± 1 [26; 29] 2.2
TK 35 37 35 36 36 36 ± 1 [35; 37] 1.8
AVR − 11 − 13 − 11 − 13 − 12 − 12 ± 1 [− 13; − 11] 1.8
#6 MT Cobb 24 22 18 18 17 20 ± 3 [17; 24] 6.6**
TK 39 41 34 36 36 37 ± 3 [34; 41] 7.4**
AVR 5 6 7 8 8 7 ± 1 [5; 8] 3.5*
#7 MT Cobb 27 25 25 25 25 26 ± 1 [25; 27] 2.5
TK 43 43 42 42 42 42 ± 1 [42; 43] 1.3
AVR − 14 − 11 − 11 − 11 − 11 − 12 ± 1 [− 14; − 11] 2.7
#8 MT Cobb 27 25 24 24 24 25 ± 1 [24; 27] 3.2*
TK 35 35 34 34 34 35 ± 0 [34; 35] 1.1
AVR − 1 3 2 3 3 2 ± 2 [− 1; 3] 4.2*
#9 MT Cobb 23 21 20 19 20 20 ± 1 [19; 23] 3.3*
TK 30 31 30 30 30 30 ± 0 [30; 31] 0.9
AVR − 6 − 5 − 4 − 4 − 4 − 5 ± 1 [− 6; − 4] 2.5
#10 MT Cobb 19 18 18 18 21 19 ± 1 [18; 21] 2.2
TK 51 51 50 50 50 50 ± 1 [50; 51] 1.9
AVR − 6 − 2 − 3 − 2 − 2 − 3 ± 2 [− 6; − 2] 3.8*

Their variability is expressed as average (Avg) ± standard deviation (SD) with range (Max–min). The double asterisk ("**") indicates the maximum variability of 3D descriptors, while a single asterisk ("*") indicates when the variability is greater than the average value calculated over all ten cases