Table 2.
Model Name | Temperature | Parameters | Control | Microwaved | Ultrasound |
---|---|---|---|---|---|
Newton | 50 °C | k × 102 (1/min) | 0.446 ± 0.005 | 0.558 ± 0.024 | 0.478 ± 0.009 |
55 °C | k × 102 (1/min) | 0.578 ± 0.015 | 0.808 ± 0.043 | 0.546 ± 0.023 | |
60 °C | k × 102 (1/min) | 0.604 ± 0.013 | 0.851 ± 0.071 | 0.608 ± 0.014 | |
Henderson & Pabis | 50 °C | a | 1.061 ± 0.007 | 1.074 ± 0.019 | 1.068 ± 0.010 |
k × 102 (1/min) | 0.481 ± 0.006 | 0.598 ± 0.026 | 0.508 ±0.010 | ||
55 °C | a | 1.068 ± 0.012 | 1.098 ± 0.025 | 1.058 ± 0.010 | |
k × 102 (1/min) | 0.615 ± 0.01 | 0.881 ± 0.046 | 0.577 ± 0.012 | ||
60 °C | a | 1.074 ± 0.018 | 1.090 ± 0.077 | 0.632 ± 0.017 | |
k × 102 (1/min) | 0.646 ± 0.026 | 0.925 ± 0.031 | 1.041 ± 0.011 | ||
Page | 50 °C | k × 102 (1/minN) | 0.169 ± 0.004 | 0.154 ± 0.015 | 0.165 ± 0.008 |
N | 1.184 ± 0.005 | 1.240 ± 0.021 | 1.191 ± 0.009 | ||
55 °C | k × 102 (1/minN) | 0.213 ± 0.014 | 0.170 ± 0.018 | 0.282 ± 0.029 | |
N | 1.186 ± 0.013 | 1.310 ± 0.023 | 1.124 ± 0.022 | ||
60 °C | k × 102 (1/minN) | 0.184 ± 0.062 | 0.177 ± 0.029 | 0.312 ± 0.019 | |
N | 1.224 ± 0.019 | 1.319 ± 0.031 | 1.126 ± 0.01 |