Table 2.

Fitting electrochemical data of the applied coatings in the simulated concrete pore (SCP) solutions.

Specimens Time (Day) Rs (Ω·cm2) Qc−1·cm−2·sn) n Rc (Ω·cm2) Qdl−1·cm−2·sn) n Rct (Ω·cm2) χ2 Equivalent Circuit
Epoxy 5 2799 3.33 × 10−10 9.3 × 10−1 2.76 × 104 0.02710 R(QR)
15 2266 3.11 × 10−10 1 1.96 × 104 7.65 × 10−5 4.48 × 10−1 1.63 × 104 0.01538 R(QR)(QR)
Epoxy-CaCO3 5 0.04873 4.54 × 10−11 1 1.59 × 105 0.02607 R(QR)
15 132 7.10 × 10−11 2.45 × 10−1 9.53 × 104 1.01 × 10−5 1 7.16 × 104 0.00910 R(QR)(QR)
Epoxy-3 wt% SLS/CaCO3 5 750 1.22 × 10−10 9.45 × 10−1 5.20 × 1010 0.04723 R (QR)
15 2930 1.09 × 10−10 1 5.16 × 1010 1.40 × 10−5 6.12 × 10−1 1.30 × 1010 0.02086 R(Q(R(QR)))
Epoxy-5 wt% SLS/CaCO3 5 3166 9.03 × 10−11 1 9.55 × 1010 0.02707 R (QR)
15 1662 1.40 × 10−10 9.79 × 10−1 4.54 × 1010 7.94 × 10−7 9.99 × 10−1 4.36 × 1010 0.03265 R(Q(R(QR)))