Average frequency (in terms of the number of maximum peaks per sequence) of the quasi-periodic signals obtained with the five ratio-based body measurements.

Dataset Speed HW1 HW2 HW3 A1 A2
Dataset 1 Slow walk 6.40 (±0.92) 6.15 (±0.78) 6.29 (±0.87) 7.03 (±1.00) 5.86 (±0.85)
Normal walk 6.86 (±0.72) 6.93 (±0.66) 6.88 (±0.73) 7.06 (±0.64) 7.21 (±0.68)
Fast walk 8.14 (±0.61) 7.60 (±1.02) 8.18 (±0.65) 8.10 (±0.65) 7.93 (±0.70)
Dataset 2 Slow walk 2.69 (±0.41) 2.76 (±0.42) 2.74 (±0.39) 3.31 (±0.45) 2.47 (±0.58)
Normal walk 2.64 (±0.42) 2.64 (±0.45) 2.68 (±0.46) 2.97 (±0.45) 2.62 (±0.50)
Fast walk 2.66 (±0.38) 2.76 (±0.36) 2.66 (±0.36) 2.88 (±0.42) 2.68 (±0.53)

HW1—ratio of the full-body height to the full-body width; HW2—ratio of the full-body height to the mid-body width; HW3—ratio of the full-body height to the lower-body width; A1—ratio of the apparent to the full-body area; A2—ratio of area between legs and full-body area.