Skip to main content
. 2021 Apr 19;10(4):801. doi: 10.3390/plants10040801

Table 3.

Effect of different blue–red light ratios in LED lighting on the growth parameters of mustard microgreens.

Treatment Hypocotyl Length,
cm
Root Length,
cm
Leaf Area,
cm2
Shoot Fresh Weight,
mg
Shoot Dry Weight,
mg
Root Fresh Weight,
mg
Root Dry Weight,
mg
Shoot-to-Root Ratio
B0R100 3.37 ± 0.10 a 6.95 ± 0.42 ab 2.43 ± 0.31 b 68.65 ± 5.07 ab 4.10 ± 0.86 a 10.82 ± 1.04 a 0.68 ± 0.03 a 5.95 ± 0.98 ab
B10R90 2.49 ± 0.14 b 6.30 ± 0.13 b 2.19 ± 0.19 b 63.20 ± 4.05 ab 4.14 ± 0.09 a 11.97 ± 0.09 a 0.75 ± 0.04 a 5.51 ± 0.16 b
B25R75 2.30 ± 0.26 b 6.53 ± 0.27 ab 2.73 ± 0.19 a 70.46 ± 4.23 ab 4.27 ± 0.48 a 12.46 ± 2.64 a 0.78 ± 0.04 a 5.46 ± 0.44 b
B50R50 2.15 ± 0.14 b 6.80 ± 0.55 ab 2.30 ± 0.15 b 60.07 ± 1.54 b 3.60 ± 0.35 b 11.60 ± 2.31 a 0.69 ± 0.09 a 5.24 ± 0.25 b
B75R25 1.38 ± 0.20 c 7.14 ± 0.23 ab 2.25 ± 0.11 b 60.99 ± 3.52 b 3.79 ± 0.24 b 11.25 ± 0.50 a 0.70 ± 0.06 a 5.43 ± 0.23 b
B100R0 3.29 ± 0.22 a 7.46 ± 0.42 a 3.08 ± 0.23 a 78.73 ± 13.21 a 4.41 ± 0.77 a 11.34 ± 1.51 a 0.62 ± 0.13 a 7.17 ± 0.79 a

B0R100, B10R90, B25R75 B50R50, B75R25, and B100R0: indicate the percentage of blue (B) and red (R) light. All values in the table are expressed as mean ± standard error (n = 3). Means with different letters are significantly different at the p < 0.05 level according to Tukey’s honestly significant difference test.