Skip to main content
. 2021 Apr 16;21(8):2822. doi: 10.3390/s21082822

Figure 14.

Figure 14

(a) Static accuracy test simulation with noisy data, two noise levels are compared. Position errors depend on model approximations and on noise magnitude. (b) Cumulative distribution function of the position error, for the two magnetic models considered and average noise levels of 50 and 65 dB.