Du 2015.

Study characteristics
Patient Sampling Cross‐sectional, consecutive, prospective
Patient characteristics and setting Presenting signs and symptoms: patients found to be smear‐negative on prior testing with radiographic evidence of pleural effusion and those subsequently undergoing thoracocentesis and pleural biopsy
Age: mean 39 years, SD 13
Sex, female: 44%
Children: 0%
HIV infection: 4%
Clinical setting: 4 tertiary care centres (inpatient)
Past history of TB: not reported
Patients on anti‐TB treatment: not reported
Number of specimens evaluated: 126
Laboratory level: central
Country: China
World Bank Income Classification: middle income
High TB burden: yes
High TB/HIV burden: yes
High MDR‐TB burden: yes
Index tests Xpert MTB/RIF
WHO SOP or manufacturer's protocol followed: yes
Manufacturer's involvement: no
Target condition and reference standard(s) Target condition: pleural TB
Reference standard for TB detection: LJ and MGIT
Reference standard for rifampicin resistance: MGIT‐DST
Speciation: yes
Decontamination: yes, NALC‐NaOH
Flow and timing  
Comparative  
Notes Study included specimens found to be smear‐negative on prior testing. In the present study, 4 specimens were smear‐positive specimens for pleural fluid and 15 were smear‐positive for pleural tissue
The reference standard for both pleural fluid and pleural tissue was pleural biopsy culture
Methodological quality
Item Authors' judgement Risk of bias Applicability concerns
DOMAIN 1: Patient Selection
Was a consecutive or random sample of patients enrolled? Yes    
Was a case‐control design avoided? Yes    
Did the study avoid inappropriate exclusions? No    
Could the selection of patients have introduced bias?   High risk  
Are there concerns that the included patients and setting do not match the review question?     High
DOMAIN 2: Index Test (Xpert MTB/RIF)
Were the index test results interpreted without knowledge of the results of the reference standard? Yes    
If a threshold was used, was it pre‐specified? Yes    
Could the conduct or interpretation of the index test have introduced bias?   Low risk  
Are there concerns that the index test, its conduct, or interpretation differ from the review question?     Low concern
DOMAIN 2: Index Test (Xpert Ultra)
DOMAIN 3: Reference Standard
Is the reference standards likely to correctly classify the target condition? Unclear    
Were the reference standard results interpreted without knowledge of the results of the index tests? Yes    
For rifampicin resistance testing, were the reference standard results interpreted without knowledge of the results of the index test? Yes    
Could the reference standard, its conduct, or its interpretation have introduced bias?   Unclear risk  
Are there concerns that the target condition as defined by the reference standard does not match the question?     Low concern
DOMAIN 4: Flow and Timing
Was there an appropriate interval between index test and reference standard? Yes    
Did all patients receive the same reference standard? Yes    
Were all patients included in the analysis? Yes    
Could the patient flow have introduced bias?   Low risk