Metcalf 2018.
Study characteristics | |||
Patient Sampling | Cross‐sectional, consecutive, prospective | ||
Patient characteristics and setting | Presenting signs and symptoms: patients presenting with a suspected diagnosis of TB meningitis Age: 18 and older Sex, female: 27% Children: No HIV infection: 62% Clinical setting: inpatient Past history of TB: 30% Participants on anti‐TB treatment: no Number of specimens evaluated: 37 Laboratory level: central Country: Peru World Bank Income Classification: middle income High TB burden: no High TB/HIV burden: no High MDR‐TB burden: yes |
||
Index tests | Xpert MTB/RIF WHO SOP or manufacturer's protocol followed: yes |
||
Target condition and reference standard(s) | TB meningitis MGIT, Ogawa Speciation: not reported |
||
Flow and timing | |||
Comparative | |||
Notes | |||
Methodological quality | |||
Item | Authors' judgement | Risk of bias | Applicability concerns |
DOMAIN 1: Patient Selection | |||
Was a consecutive or random sample of patients enrolled? | Yes | ||
Was a case‐control design avoided? | Yes | ||
Did the study avoid inappropriate exclusions? | Yes | ||
Could the selection of patients have introduced bias? | Low risk | ||
Are there concerns that the included patients and setting do not match the review question? | Low concern | ||
DOMAIN 2: Index Test (Xpert MTB/RIF) | |||
Were the index test results interpreted without knowledge of the results of the reference standard? | Yes | ||
If a threshold was used, was it pre‐specified? | Yes | ||
Could the conduct or interpretation of the index test have introduced bias? | Low risk | ||
Are there concerns that the index test, its conduct, or interpretation differ from the review question? | Low concern | ||
DOMAIN 2: Index Test (Xpert Ultra) | |||
DOMAIN 3: Reference Standard | |||
Is the reference standards likely to correctly classify the target condition? | Yes | ||
Were the reference standard results interpreted without knowledge of the results of the index tests? | Unclear | ||
For rifampicin resistance testing, were the reference standard results interpreted without knowledge of the results of the index test? | Unclear | ||
Could the reference standard, its conduct, or its interpretation have introduced bias? | Unclear risk | ||
Are there concerns that the target condition as defined by the reference standard does not match the question? | Unclear | ||
DOMAIN 4: Flow and Timing | |||
Was there an appropriate interval between index test and reference standard? | Yes | ||
Did all patients receive the same reference standard? | Yes | ||
Were all patients included in the analysis? | Yes | ||
Could the patient flow have introduced bias? | Low risk |