. 2021 Apr 15;2021(4):CD013346. doi: 10.1002/14651858.CD013346.pub2

Buffet 1988.

Study characteristics
Patient Sampling A retrospective study of 217 patients admitted to hospital (Paris France) with liver cirrhosis
Age range: 16‐85. Males 63%
Patient characteristics and setting  
Index tests AFP measurement with a cut‐off level 250 mcg/mL; US: any focal lesion or diffuse heterogeneity with venous distortion; AFP > 250 + US
Target condition and reference standard(s) HCC: histology, CT arteriography or AFP > 250 ng/mL, or clinical follow‐up (undefined interval)
Flow and timing No information on interval between index test and reference standard
Comparative  
Notes No information on funding or conflicts of interest
Methodological quality
Item Authors' judgement Risk of bias Applicability concerns
DOMAIN 1: Patient Selection
Was a consecutive or random sample of patients enrolled? No    
Was a case‐control design avoided? Yes    
Did the study avoid inappropriate exclusions? No    
Could the selection of patients have introduced bias?   High risk  
Are there concerns that the included patients and setting do not match the review question?     Low concern
DOMAIN 2: Index Test (AFP)
Were the index test results interpreted without knowledge of the results of the reference standard? Yes    
If a threshold was used, was it pre‐specified? Yes    
Could the conduct or interpretation of the index test have introduced bias?   Low risk  
Are there concerns that the index test, its conduct, or interpretation differ from the review question?     Low concern
DOMAIN 2: Index Test (US+AFP)
Were the index test results interpreted without knowledge of the results of the reference standard? Yes    
If a threshold was used, was it pre‐specified? Yes    
Could the conduct or interpretation of the index test have introduced bias?   Low risk  
Are there concerns that the index test, its conduct, or interpretation differ from the review question?     Low concern
DOMAIN 2: Index Test (US)
Were the index test results interpreted without knowledge of the results of the reference standard? Yes    
If a threshold was used, was it pre‐specified? Yes    
Could the conduct or interpretation of the index test have introduced bias?   Low risk  
Are there concerns that the index test, its conduct, or interpretation differ from the review question?     Low concern
DOMAIN 3: Reference Standard
Is the reference standards likely to correctly classify the target condition? No    
Were the reference standard results interpreted without knowledge of the results of the index tests? No    
Could the reference standard, its conduct, or its interpretation have introduced bias?   High risk  
Are there concerns that the target condition as defined by the reference standard does not match the question?     High
DOMAIN 4: Flow and Timing
Was there an appropriate interval between index test and reference standard? Unclear    
Did all patients receive the same reference standard? No    
Were all patients included in the analysis? No    
Could the patient flow have introduced bias?   High risk