Skip to main content
. 2021 Apr 15;2021(4):CD013346. doi: 10.1002/14651858.CD013346.pub2

el‐Houseini 2005.

Study characteristics
Patient Sampling Blood samples were collected from patients at the National Cancer Institute (NCI) of Cairo during a 1‐year period. Patients were diagnosed according to radiological imaging, laboratory tests, and clinical investigation following the institutional protocol. Two groups: 44 patients with HCC and 20 patients with cirrhosis but without HCC.
Age range not reported. Males 72%
Patient characteristics and setting  
Index tests A commercially available microparticle enzyme immunoassay was used to determine the serum level of AFP expressed in ng/mL, with no prespecified cut‐off value.
Target condition and reference standard(s) Patients were diagnosed according to radiological imaging, laboratory tests, and clinical investigation following the institutional protocol.
Flow and timing No information on interval between index test and reference standard
Comparative  
Notes No information on funding or conflicts of interest
Methodological quality
Item Authors' judgement Risk of bias Applicability concerns
DOMAIN 1: Patient Selection
Was a consecutive or random sample of patients enrolled? No    
Was a case‐control design avoided? No    
Did the study avoid inappropriate exclusions? Unclear    
Could the selection of patients have introduced bias?   High risk  
Are there concerns that the included patients and setting do not match the review question?     High
DOMAIN 2: Index Test (AFP)
Were the index test results interpreted without knowledge of the results of the reference standard? Yes    
If a threshold was used, was it pre‐specified? No    
Could the conduct or interpretation of the index test have introduced bias?   High risk  
Are there concerns that the index test, its conduct, or interpretation differ from the review question?     Low concern
DOMAIN 2: Index Test (US+AFP)
DOMAIN 2: Index Test (US)
DOMAIN 3: Reference Standard
Is the reference standards likely to correctly classify the target condition? Unclear    
Were the reference standard results interpreted without knowledge of the results of the index tests? Yes    
Could the reference standard, its conduct, or its interpretation have introduced bias?   Unclear risk  
Are there concerns that the target condition as defined by the reference standard does not match the question?     High
DOMAIN 4: Flow and Timing
Was there an appropriate interval between index test and reference standard? Unclear    
Did all patients receive the same reference standard? Unclear    
Were all patients included in the analysis? Yes    
Could the patient flow have introduced bias?   Unclear risk