Skip to main content
. 2021 Apr 15;2021(4):CD013346. doi: 10.1002/14651858.CD013346.pub2

Ismail 2017b.

Study characteristics
Patient Sampling The studied patients and controls were divided into the following groups:
Group I (GI): included 30 patients with liver cirrhosis
Group II (GII): included 30 cirrhotic patients with HCC fulfilling HCC criteria on tri‐phasic CT scan
Group III (GIII): included 30 healthy individuals
Exclusion criteria: a past history or evidence of other malignancies, autoimmune disorders, organ failure, and other causes of cirrhosis (e.g. alcoholic and non‐alcoholic fatty liver diseases).
Age range not reported. Males 55%
Patient characteristics and setting  
Index tests Serum AFP: no specification. No definition of the cut‐off value
Target condition and reference standard(s) All studied groups were subjected to abdominal ultrasound, while GI and GII were subjected to Tri‐phasic CT scan abdomen.
Flow and timing No information on interval between index test and reference standard
Comparative  
Notes No information on conflicts of interest
Methodological quality
Item Authors' judgement Risk of bias Applicability concerns
DOMAIN 1: Patient Selection
Was a consecutive or random sample of patients enrolled? No    
Was a case‐control design avoided? No    
Did the study avoid inappropriate exclusions? No    
Could the selection of patients have introduced bias?   High risk  
Are there concerns that the included patients and setting do not match the review question?     High
DOMAIN 2: Index Test (AFP)
Were the index test results interpreted without knowledge of the results of the reference standard? Yes    
If a threshold was used, was it pre‐specified? No    
Could the conduct or interpretation of the index test have introduced bias?   High risk  
Are there concerns that the index test, its conduct, or interpretation differ from the review question?     Low concern
DOMAIN 2: Index Test (US+AFP)
Were the index test results interpreted without knowledge of the results of the reference standard?      
If a threshold was used, was it pre‐specified?      
Could the conduct or interpretation of the index test have introduced bias?      
Are there concerns that the index test, its conduct, or interpretation differ from the review question?      
DOMAIN 2: Index Test (US)
Were the index test results interpreted without knowledge of the results of the reference standard?      
If a threshold was used, was it pre‐specified?      
Could the conduct or interpretation of the index test have introduced bias?      
Are there concerns that the index test, its conduct, or interpretation differ from the review question?      
DOMAIN 3: Reference Standard
Is the reference standards likely to correctly classify the target condition? Yes    
Were the reference standard results interpreted without knowledge of the results of the index tests? Yes    
Could the reference standard, its conduct, or its interpretation have introduced bias?   Low risk  
Are there concerns that the target condition as defined by the reference standard does not match the question?     Low concern
DOMAIN 4: Flow and Timing
Was there an appropriate interval between index test and reference standard? Unclear    
Did all patients receive the same reference standard? Yes    
Were all patients included in the analysis? Yes    
Could the patient flow have introduced bias?   Unclear risk