Raff 2014.
Study characteristics | |||
Patient Sampling | The cross‐sectional study included 366 patients with cirrhosis, of whom supposedly all had AFP sampled. 163 patients received US as screening test. The AFP analysis included 356 patients ‐ 10 patients excluded without explanation. Medical charts of patients with cirrhosis seen at a single tertiary referral centre (2007‐2011) were reviewed. Among other data, use of and findings from CT or MRI scan within 6 months of receiving US were recorded for patients who had US as the initial imaging. Age range not reported. Males 71% |
||
Patient characteristics and setting | |||
Index tests | AFP cut‐off level 20 ng/mL; US no specification | ||
Target condition and reference standard(s) | HCC: HCC was diagnosed based on standard criteria on CT or MRI scan. Of 163 patients receiving US, 72 received follow‐up CT/MRI scan within 6 months of US examination. |
||
Flow and timing | Use of and findings from CT or MRI scan within 6 months of receiving US was recorded for patients who had US as the initial imaging. No information for AFP. The AFP analysis included 356 patients. 10 patients excluded without explanation |
||
Comparative | |||
Notes | No information on conflicts of interest | ||
Methodological quality | |||
Item | Authors' judgement | Risk of bias | Applicability concerns |
DOMAIN 1: Patient Selection | |||
Was a consecutive or random sample of patients enrolled? | No | ||
Was a case‐control design avoided? | Yes | ||
Did the study avoid inappropriate exclusions? | No | ||
Could the selection of patients have introduced bias? | High risk | ||
Are there concerns that the included patients and setting do not match the review question? | Low concern | ||
DOMAIN 2: Index Test (AFP) | |||
Were the index test results interpreted without knowledge of the results of the reference standard? | Yes | ||
If a threshold was used, was it pre‐specified? | Yes | ||
Could the conduct or interpretation of the index test have introduced bias? | Low risk | ||
Are there concerns that the index test, its conduct, or interpretation differ from the review question? | Low concern | ||
DOMAIN 2: Index Test (US+AFP) | |||
DOMAIN 2: Index Test (US) | |||
Were the index test results interpreted without knowledge of the results of the reference standard? | Yes | ||
If a threshold was used, was it pre‐specified? | No | ||
Could the conduct or interpretation of the index test have introduced bias? | High risk | ||
Are there concerns that the index test, its conduct, or interpretation differ from the review question? | Low concern | ||
DOMAIN 3: Reference Standard | |||
Is the reference standards likely to correctly classify the target condition? | No | ||
Were the reference standard results interpreted without knowledge of the results of the index tests? | No | ||
Could the reference standard, its conduct, or its interpretation have introduced bias? | High risk | ||
Are there concerns that the target condition as defined by the reference standard does not match the question? | Low concern | ||
DOMAIN 4: Flow and Timing | |||
Was there an appropriate interval between index test and reference standard? | No | ||
Did all patients receive the same reference standard? | No | ||
Were all patients included in the analysis? | No | ||
Could the patient flow have introduced bias? | High risk |