Skip to main content
. 2021 Apr 27;10(4):30. doi: 10.1167/tvst.10.4.30

Table 3.

Comparison of the Study Parameters Between Eyes With Previous ON and Fellow Eyes of the 11 Patients With MS With a History of Unilateral ON

ON Eye (n = 11) Non-ON Eye (n = 11) P Valuea Cohen's d Effect Size
Initial pupil diameter (mm) 5.12 ± 0.79 5.15 ± 0.87 0.936 −0.0870
Contraction amplitude (mm) 1.56 ± 0.49 1.57 ± 0.42 0.961 −0.0963
Percentage change in size (%) 30.1 ± 6.7 30.4 ± 5.3 0.926 −0.0948
Contraction latency (ms) 268.0 (238.0–307.0) 269.0 (243.0–293.0) 0.889 −0.0911
Contraction duration (ms) 561.8 ± 85.2 558.9 ± 71.4 0.928 0.0543
Contraction velocity (mm/s) 5.47 (4.34–5.97) 5.06 (4.73–5.84) 0.920 −0.1999
Dilation latency (ms) 834.0 (737.0–869.0) 834.0 (767.0–869.0) 0.983 −0.0099
Dilation duration (ms) 1631.0 (1601.0–1670.0) 1637.0 (1630.0–1703.0) 0.700 −0.1749
Dilation velocity (mm/s) 2.02 ± 0.32 1.95 ± 0.43 0.623 0.2115
RNFL thickness (µm) 83.9 ± 15.7 91.8 ± 13.4 0.223 −0.7297

Data are expressed as mean ± SD for parametric variables and median (IQR) for nonparametric variables.

a