Skip to main content
. 2021 Apr 28;41(17):3870–3878. doi: 10.1523/JNEUROSCI.2785-20.2021

Table 1.

Demographic, clinical, and behavioral performance information for three cases

Case 1 Case 2 Case 3
Age 18 28 20
Gender Female Female Male
Handedness Left Right Right
Years of education 11 years 19 years 13 years
Duration of epilepsy 2 years 18 years 8 years
Treatment Medicine: oxcarbazepine
    Surgery: radio frequency thermocoagulation through depth electrodes after SEEG monitoring
Medicine: oxcarbazepine, levetiracetam
    Surgery: radio frequency thermocoagulation through depth electrodes after SEEG monitoring
Medicine: lamotrigine, zonisamide, and lacosamide
    Surgery: responsive neurostimulation targeting posterior locations
Seizure types Focal aware; focal aware to bilateral tonic–clonic Focal impaired awareness; focal impaired awareness to bilateral tonic–clonic Focal impaired awareness to bilateral tonic–clonic
Video-EEG results Right frontal lobe epileptic discharges Left frontal and anterior-middle temporal spikes and irregular slow waves Right occipito-temporal onset seizure with right posterior slowing of ongoing rhythm
Behavioral results Average city-error rate of 1.2% (range: 1–2%) and average mountains-error rate of 19% (range: 7–30%) Average city-error rate of 1.1% (range: 1–1.2%) and average mountains-error rate of 13.3% (range: 10–18%) Average city-error rate of 4.2% (range: 2–5%) and average mountains-error rate of 58% (range: 40–70%)
SEEG results Total of 182 SEEG electrodes, 24 within the PVH tissue.
    Functionally active electrodes: 7 of 24 PVH, 56 of 158 non-PVH electrodes.
    Epileptic sites within active sites: 2 of 7 active PVH sites and 17 of 56 active non-PVH were epileptic.
Total of 144 SEEG electrodes, 26 within the PVH tissue.
    Functionally active electrodes: 5 of 26 PVH, 3 of 118 non-PVH electrodes.
    Epileptic sites within active sites: 5 of 5 active PVH sites and 3 of 3 active non-PVH were epileptic.
Total of 140 SEEG electrodes, 38 within the PVH tissue.
    Functionally active electrodes: 10 of 38 PVH, 16 of 102 non-PVH electrodes.
    Epileptic sites within active sites: 1 of 10 active PVH sites and 7 of 16 active non-PVH were epileptic.

City-errors (or omission errors) are mistakes when a button press should be made but are missed; mountain-errors (or commission errors) are mistakes when a button press should be withheld but the button is pressed. Rate and range are given for the blocks done. PVH, periventricular heterotopia; EEG, electroencephalography; SEEG, stereo-EEG.