Skip to main content
. 2021 Apr 16;15:647930. doi: 10.3389/fnbot.2021.647930

Table 3.

Accuracy and predictability of the AoI features considering different fixation times for comparison with the fixation times of 1.5 s used by Shafti et al. (2019) and of 2 s used by Wang et al. (2018).

Configuration (fixation time) Lined-up (Δt = 0.5) Triangle (Δt = 0.5) Lined-up (Δt = 1.5) Triangle (Δt = 1.5) Lined-up (Δt = 2.0) Triangle (Δt = 2.0) Lined-up (Δt = 0.9) Triangle (Δt = 1.3)
Accuracy 66.0% 62.4% 52.1% 54.3% 42.6% 48.8% 61.0% 56.3%
Predictability 47.0% 53.8% 24.1% 35.0% 16.1% 28.4% 37.0% 37.9%

Since in general shorter fixation times occurred in the trials, also a shorter 0.5 s interval was tested. A further comparison is done using a fixation time equal to the window times used in our model (Δt = {0.9, 1.3s}).