Table 3. Analysis of the reactors incubated for 24 hours with MRC5 cells.

Number of cells Electrode Control, supernatant or cells |Ilim|1 (μA) Potential (E) at 5 μA (V/ref) Shift vs. control ΔE at 5 μA (mV)
50 000 C control 8.6 -0.152 -
supernatant 8.0 -0.125 27
cells 6.6 -0.065 87
CNT control 8.0 -0.099 -
supernatant 8.7 -0.081 18
cells 6.0 -0.060 39
C control 8.5 -0.154 -
supernatant 7.9 -0.098 56
cells 5.5 -0.065 89
CNT control 8.4 -0.205 -
supernatant 9.1 -0.194 11
cells 5.3 -0.061 144
200 000 C control 8.9 -0.141 -
supernatant 8.1 -0.065 76
cells 2.9 nd 2 nd 2
CNT control 8.0 -0.110 -
supernatant 8.5 -0.054 56
cells 4.7 -0.088 22

1 Ilim is the value of the current at the lower potential limit of the CV records (-0.4 V/ref) minus the capacitive current measured at 0.2V/ref.

2 the curve did not reach 5 μA.