Table 2.

Comparison of the gold standard manual pipeline and the automatic pipeline.

Pipeline type Manual pipeline Automated pipeline
Image acquisition (measurement time) 8.4 min 8.4 min
Segmentation 15–30 min19 0.5 min
vBMD measurement 1 min 1 min
Total time 24.4–39.4 min 9.9 min
Speedup (with respect to manual pipeline) 1 2.5–4.0

Manual and automatic pipeline only differ in the segmentation step. For the manual pipeline an expert has to annotate the patient’s slices semi-automatically while for the automatic pipeline, a neural network predicts the location of the second MC. Both network variants, the 2D U-Net and the 3D U-Net have similar run times for the segmentation task. Differences of time between manual pipeline and automated pipeline are highlighted in bold font.