. 2021 Apr 23;12:609821. doi: 10.3389/fmicb.2021.609821

FIGURE 4.

FIGURE 4

Analytical sensitivity of Visual LAMP assay. (A) Comparative analytical sensitivity of visual LAMP (open circles) and the gold standard qPCR (closed circles) using plasmid standards. (B) The visual LAMP results of the plasmid standards, number 1 to 8 represent 106 copies/μL, 105 copies/μL, 104 copies/μL, 103 copies/μL, 102 copies/μL, 101 copies/μL, 100 copies/μL, and negative control, respectively. Positive reactions are shown by “+” and negative reactions are shown by “-”. (C) Determining the visual LAMP products by agarose gel electrophoresis. From left to right: lane M, DNA Marker DL-2000 (Takara); lanes 1-8, different copy number subjected to visual LAMP assay (106 copies/μL, 105 copies/μL, 104 copies/μL, 103 copies/μL, 102 copies/μL, 101 copies/μL, 100 copies/μL and negative control, respectively).