Table 1.

Journal-defined custom variables

AcquireSettingFile used in Load Autofocus Acquire Settings to define the file to be loaded
AcquireSettings binary (Y/N) variable used in TMA Scanning Master to confirm that focus acquire settings have been set and saved correctly
ActiveImage binary (Y/N) variable used in TMA Scanning Master to confirm that Stage list array.tif is open and active when using an existing stage list array file
AugmentRegionNumber defined in AddToAllROINumbers and used in IncreaseROINumbers to indicate the constant value to be added when renumbering a set of ROIs
BottomRightX used in Region label to array (or Region label to array (existing stage list array)) and used in SlideZ focus to define location of ROI designated for use in determining the central focal plane of each slide
BottomRightY used in Region label to array (or Region label to array (existing stage list array)) and used in SlideZ focus to define location of ROI designated for use in determining the central focal plane of each slide
column used in Segment TMA to define the grid
CurrentDpZ used in scan slide adjust to track the most recent deep focus result within an ROI
CurrentSlide used in SlideZ focus, scan tissue, and ROI focus and determined based on FirstROI variable
CurrentX, CurrentY used in SlideZ focus and ROIZ focus to track stage position
Difference used in Threshold finder to report the calculated threshold for the current image
Directory defined by the Scan Slide variable ScanSlide.Directory and used in scan tissue
DpFocCh defined in TMA Scanning Master and used in scan slide adjust to encode the channel, i.e. illumination settings, used for deep focusing
DpFocChk used in scan slide adjust as counter to determine when a deep focus should be performed within an ROI
DpFocExp defined in scan slide adjust to record value for entry into the summary log
DpFocInt defined in TMA Scanning Master and used in scan tissue and scan slide adjust to indicate number of tiles imaged before deep focusing within an ROI
DpFocRange defined in TMA Scanning Master and used in scan slide adjust to indicate the range, in microns, to be scanned when deep focusing within an ROI
DpStepSz defined in TMA Scanning Master and used in scan slide adjust to indicate the size, in microns, of steps used when deep focusing within an ROI
DpFocVar defined in TMA Scanning Master and used in scan slide adjust to indicate the size, in microns, of the acceptable difference in z between a newly identified focal point and the previous deep focal point when deep focusing
DpThreshold defined in TMA Scanning Master and used in scan slide adjust to indicate the threshold used to determine if tissue is present when deep focusing
EndTime defined in TMA Scanning Master and used in Record variables.
ErrorCode Used in ROI focus and ROITissueNotFound.
FirstROINumber used in Segment TMA to define the grid
FirstROIPos1 binary (Y/N) variable used in TMA Scanning Master to ask if the first ROI on slide 1 is numbered 1
FirstROISlide1, FirstROISlide2, FirstROISlide3, FirstROISlide4 defined in TMA Scanning Master and used in SlideZ focus, scan tissue, and ROI focus to indicate the number of the first ROI on each slide.
FirstSubZ numerical variable defined in ROI focus and used in scan slide adjust to tag the first tile within an ROI and to track the degree of discordance between previous and new focus positions
FnFocCh defined in TMA Scanning Master and used in scan slide adjust to record the channel, i.e. illumination settings, used for fine focusing within an ROI
FnFocChk introduced in scan tissue and used in scan slide adjust as a counter to determine when a fine focus should be performed within an ROI
FnFocExp defined in scan slide adjust for entry into the summary log
FnFocInt introduced in TMA Scanning Master and used in scan tissue and scan slide adjust to indicate the number of tiles imaged before fine focusing is performed within an ROI
FnFocRange introduced in TMA Scanning Master and used in scan slide adjust to indicate the range, in microns, to be scanned when fine focusing within an ROI
FnFocStepSz introduced in TMA Scanning Master and used in scan slide adjust to indicate the size, in microns, of steps used when fine focusing within an ROI.
FnFocVar introduced in TMA Scanning Master and used in scan slide adjust; the size, in microns, of the acceptable difference in z between a newly identified focal point and the previous fine focal point when fine focusing within an ROI
FnThreshold introduced in TMA Scanning Master and used in scan slide adjust to indicate the threshold used to determine if tissue is present in scan slide adjust
Focus binary (Y/N) variable used in TMA Scanning Master to ask if z-origin is set and correct objective is in place
FocusChannel defined by user in TMA Scanning Master and FocusAcquireSettings, used in Load Autofocus Acquire Settings, SlideZ Focus, ROI focus, and scan slide adjust to pass current focus channel information between journals
FocusROISlide1, FocusROISlide2, FocusROISlide3, FocusROISlide4 introduced in TMA Scanning Master and used in Region label to array (or Region label to array (existing stage list array)) to indicate the number of the ROI to be used in determining the central focal plane of each slide
Height used in SlideZ focus and ROI focus to direct stage y movements within the ROI
Homed binary (Y/N) variable used in TMA Scanning Master to ask if stage is calibrated.
HowFarToMoveX used in SlideZ focus and ROI focus to direct stage x movements within the ROI
HowFarToMoveY used in SlideZ focus and ROI focus to direct stage y movements within the ROI
InitialZ defined in TMA Scanning Master and used in SlideZ focus to record stage z position at start of TMA Scanning Master
Label used in Region label to array and Region label to array (existing stage list array) to record the numerical value of the region label
LoadSave used in LoadSaveRescanSettings to indicate whether settings are being loaded or saved
Mag used in TMA Scanning Master, Review Scans, and Stich, Stack and Save Images to record the magnification setting used during TMA scanning
message used in TMA Scanning Master, SlideZ focus, ROI focus, and Record variables to create text for entry into the summary log
moveXY used in SlideZ focus and ROI focus to control how far in x and y directions the stage moves when focusing; the default value of 4 moves the stage 1/4 of the total width or height of the ROI
Name used in scan tissue as string variable defined by Image.StageLabel for creating scan file name
NewArray binary (Y/N) variable used in TMA Scanning Master to ask if a stage list array file needs to be created
NewDirectory used in Stitch Stack and Save Images to define \stitched_stacks directory
NumberofScans used in Review Scans and Stitch Stack and Save Images to calculate file names
Path used in Review Scans and Stitch Stack and Save Images to calculate file names
Pattern integer string used in SlideZ focus and ROI focus to move the xy stage within the ROI when determining focus points
Position integer variable that increments for each plane in the stage list array file in add top left or bottom right position to array and Region label to array (or Region label to array (existing stage list array)) after being set to 1 in TMA Scanning Master
ReducedDpThreshold defined in DpFnFocusSettings or in response to prompts and used as lower threshold in scan slide adjust
ReducedFnThreshold defined in DpFnFocusSettings or in response to prompts and used as lower threshold in scan slide adjust
ReducedROIZCount defined and used in ROITissueNotFound to track the number of times a focal point has been determined
ReducedROIZThreshold defined in SlideROIFocusSettings or in response to prompts and used as lower threshold in ROITissueNotFound
RegionColumn used in transfer shrink transfer TMA to number ROIs
RegionRow used in transfer shrink transfer TMA to number ROIs
RepeatSlideROIZCount defined and used in SlideZ-TissueNotFound to track the number of times a focal point has been determined
RepeatTotalZThreshold defined in SlideROIFocusSettings or in response to prompts and used as lower threshold in SlideZ-TissueNotFound
ReviseThreshold defined in ROITissueNotFound and used scan slide adjust to indicate that reduced deep and fine focus thresholds should be used when identifying tissue
ROI used in Review Scans and Stitch Stack and Save Images to calculate file names
ROIDirectory used in OpenPrelimAndROIs and LoadAdjustedRegions to track the directory where the preliminary scan and ROIs are stored.
ROIgroup used in Save all slide ROIs to determine which ROI group is being saved
ROISetCount used in Reload ROIs to count the sets being loaded
ROISetLoad used in Reload One ROI Set to determine which ROI set should be loaded
ROISetNumber used in Save and clear ROIs to determine which ROI set is being saved
ROISetsTotal used in Reload ROIst o determine how many ROI sets will be loaded
ROIZ used in ROI focus to record z origin of each ROI
ROIZ1, ROIZ2, ROIZ3 temporary variables used in ROI focus to record focal points
ROIZcount used in ROI focus to track the number of times a focal point has been determined
ROIZFocCh defined in TMA Scanning Master and used in ROI focus to indicate the channel, i.e. illumination settings, used to determine the origin focal plane for each ROI
ROIZFocExp defined in ROI focus to retains value for entry into the summary log
ROIZFocRange defined in TMA Scanning Master and used in ROI focus to indicate the range, in microns, to be scanned in determining the origin focal plane for each ROI
ROIFocSettings binary (Y/N) variable used in TMA Scanning Master to ask if the default (hard coded) settings will be used for ROI focus
ROIZFocStepSz defined in TMA Scanning Master and used in ROI focus to indicate the size, in microns, of steps used when determining the origin focal plane for each ROI
ROIZFocVar defined in TMA Scanning Master and used in ROI focus to indicate the size, in microns, of the acceptable difference in z between two identified focal points when determining the origin focal plane for each ROI
ROIZThreshold defined in TMA Scanning Master and used in ROI focus to indicate the threshold used to determine if tissue is present in ROI focus.
row used in Segment TMA to define the grid
ScanName used in Review Scans and Stitch Stack and Save Images to store temporary file names
ScanslideCheck used in TMA Scanning Master to query user about Scan Slide settings
ScanslideFocSettings used in TMA Scanning Master to query user about Scan Slide settings
ScanSlideSettingFile used in SaveCurrentAndUsedSettings to record the Scan Slide save directory
ScanSettings binary (Y/N) variable used in TMA Scanning Master to confirm that settings have been entered correctly
SkipConfigurationQuestions used in TMA Scanning Master to bypass configuration questions
slide used in segment TMA to record the number of the slide for which ROIs are being defined
Slide1Z, Slide2Z, Slide3Z, Slide4Z introduced in TMA Scanning Master and used in SlideZ focus and ROI focus to record of central focal plane for each slide.
SlideFocSettings binary (Y/N) variable used in TMA Scanning Master to ask if the default (hard coded) slide and ROI focus settings will be used
SlideLayout binary (Y/N) variable used in TMA Scanning Master to ask if the default (hard coded) slide layout will be used
SlideROIZ1 introduced in TMA Scanning Master and used in SlideZ focus to record focal points determined within SlideZ focus
SlideROIZ2, SlideROIZ3 used in SlideZ focus to record focal points determined within SlideZ focus
SlideROIZcount used in SlideZ focus to track the number of times a focal point has been determined
SlideZ introduced in TMA Scanning Master and used in SlideZ focus as temporary variable to record central focal plane determined for slide (based on designated ROI)
SlideZFocExp defined in SlideZ Focus for entry into the summary log
SSfocus binary (Y/N) variable used in TMA Scanning Master to ask if focusing journals are used within Scan Slide
Stage position used in add top left or bottom right position to array
StartImage defined in segment TMA and used in transfer shrink transfer TMA journals
StartingScan used in Review Scans and Stitch Stack and Save Images to calculate file names
StartTime defined in TMA Scanning Master and used in Record variables
SubZ used in scan slide adjust and before each image set the Z to track the most recent fine focus result within an ROI
SuitePath used in Load Autofocus Acquire Settings to detrermine where the journals and acquire settings are stored
tempdir used in TMA Scanning Master and Review Scan Summary to hold the path and file name for the Edge List Log file
TissuePresent used in SlideZ focus and ROI focus to indicate that, based on scaling and threshold variables, tissue is present in the field imaged
TissuePresentDp used in scan slide adjust to determine if tissue is present, based on scaling and threshold variables, before deep focusing.
TissuePresentFn used in scan slide adjust to determine if tissue is present, based on scaling and threshold variables, before fine focusing
TopLeftX used in Region label to array (or Region label to array (existing stage list array)) and SlideZ focus to define location of ROI designated for use in determining the central focal plane of each slide
TopLeftY used in Region label to array (or Region label to array (existing stage list array)) and SlideZ focus to define location of ROI designated for use in determining the central focal plane of each slide
TotalPlanes introduced in TMA Scanning Master and used in Region label to array existing stage list array) to indicate number of planes in existing stage list array file
TotalSlideNumber used in TMA Scanning Master to indicate number of slides on stage
TotalZFocCh introduced in TMA Scanning Master and used in SlideZ focus to indicate the channel, i.e. illumination settings, used to determine the central focal plane of each slide
TotalZFocStepSz introduced in TMA Scanning Master and used in SlideZ focus to indicate the size, in microns, of steps used when determining the central focal plane of each slide
TotalZFocVar introduced in TMA Scanning Master and used in SlideZ focus to indicate the size, in microns, of the acceptable difference in z between two identified focal points when determining the central focal plane of each slide
TotalZRange introduced in TMA Scanning Master and used in SlideZ focus to indicate the range, in microns, to be scanned in determining the central focal plane of each slide
TotalZThreshold introduced in TMA Scanning Master and used in SlideZ focus to indicate the threshold used to determine if tissue is present in SlideZ focus
Width used in SlideZ focus and ROI focus to direct stage x movements within the ROI
Xrange used in SlideZ focus and ROI focus to direct stage x movements within the ROI
Yrange used in SlideZ focus and ROI focus to direct stage y movements within the ROI