Skip to main content
. 2021 Jan 27;37(5):1767–1779. doi: 10.1007/s10554-020-02130-x

Table 2.

Low-dose perfusion measurement and reference standard perfusion measurement accuracy and precision analysis

Condition Slope Intercept Pearson's r Lin’s CCC RMSE
(mL/min/g)
RMSD
(mL/min/g)
STRESS + REST
LAD

1.04

[0.92, 1.15]

− 0.09

[− 0.29, 0.11]

0.95

[0.91, 0.97]

0.95

[0.90, 0.97]

0.28 0.28
LCx

1.01

[0.87, 1.16]

− 0.05

[− 0.33, 0.22]

0.96

[0.90, 0.98]

0.95

[0.90, 0.98]

0.32 0.32
RCA

1.09

[0.89, 1.30]

− 0.13

[− 0.45, 0.18]

0.92

[0.82, 0.96]

0.90

[0.79, 0.96]

0.37 0.36
ALL

1.04

[0.96, 1.12]

− 0.08

[− 0.22, 0.05]

0.94

[0.92, 0.96]

0.94

[0.91, 0.96]

0.32 0.32
STRESS
LAD

1.06

[0.88, 1.25]

− 0.14

[− 0.51, 0.23]

0.92

[0.84, 0.97]

0.91

[0.82, 0.96]

0.31 0.31
LCx

0.98

[0.76, 1.20]

0.04

[− 0.47, 0.55]

0.92

[0.80, 0.97]

0.92

[0.79, 0.97]

0.36 0.36
RCA

1.13

[0.73, 1.54]

− 0.20

[− 0.94, 0.54]

0.83

[0.59, 0.93]

0.79

[0.51, 0.92]

0.41 0.40
ALL

1.04

[0.91, 1.16]

− 0.07

[− 0.33, 0.19]

0.90

[0.85, 0.94]

0.89

[0.83, 0.94]

0.36 0.36
REST
LAD

0.41

[− 0.17, 0.99]

0.32

[− 0.06, 0.71]

0.47

[− 0.18, 0.83]

0.45

[− 0.21, 0.83]

0.19 0.15
LCx

0.81

[− 0.28, 1.91]

0.03

[− 0.67, 0.73]

0.60

[− 0.18, 0.92]

0.52

[− 0.29, 0.90]

0.20 0.17
RCA

0.46

[− 0.48, 1.39]

0.16

[− 0.32, 0.64]

0.44

[− 0.39, 0.87]

0.40

[− 0.42, 0.86]

0.25 0.20
ALL

0.60

[0.24, 0.97]

0.16

[− 0.07, 0.38]

0.56

[0.23, 0.78]

0.53

[0.19, 0.76]

0.21 0.18

Brackets indicate 95% confidence intervals

LAD left anterior descending perfusion territory, LCx left circumflex perfusion territory, RCA right coronary artery perfusion territory, ALL all coronary perfusion territories combined, Lin’s CCC Lin’s concordance correlation coefficient, RMSE root-mean-square error, RMSD root-mean-square deviation