A ranked list in descending order of the fixed effects that were found to be significant (p<0.05) in mixed effects model B for abdomen-pelvis and chest exams. For discrete features with sublevels, only the sublevel with largest t-value magnitude is shown. Features that appear toward the top of the list are more impactful on the corresponding outcome.

  Abdomen-pelvis Chest
Noise Resolution Dose Noise Resolution Dose
1 Slice thickness Scanner model Eff. diameter Slice thickness Kernel Eff. diameter
2 Patient sex Recon. FOV mAs Patient sex Recon. FOV mAs
3 AP. mis-centering AP. mis-centering kVp Recon. FOV AP. mis-centering kVp
4 Recon. FOV Patient sex Scanner model AP. mis-centering Scanner model Scanner model
5 mAs Kernel Bowtie filter Kernel Slice thickness Total collimation
6 kVp mAs AP. mis-centering kVp Pitch Recon. FOV
7 Lat. mis-centering kVp Recon. FOV Scanner model Eff. diameter Patient sex
8 Eff. diameter Total collimation Total collimation Eff. diameter   Bowtie filter
9 Kernel Slice thickness Slice thickness mAs   AP. mis-centering
10 Rotation time   Kernel Rotation time   Lat. mis-centering
11 Scanner model   Rotation time Lat. mis-centering   Pitch
12 Total collimation   Patient sex Total collimation   Kernel
13     Pitch Pitch