1. All reported adverse events.

Study ID Alternating pressure (active) air surfaces Foam surfaces Comment
Nixon 2019 Related and unexpected serious adverse events: 0
Expected adverse events/ serious adverse events: 163/1017
The proportion of deaths: 82/1017, 8.1%
Re‐admission rates: 82/1017, 8.1%
Fall rates: 152/1017, 14.9%
Related and unexpected serious adverse events: 0
Expected adverse events/ serious adverse events: 167/1013
The proportion of deaths: 84/1013, 8.3%
Re‐admission rates: 62/1013, 6.1%
Fall rates: 159/1013, 15.7%
Similar between groups
Rosenthal 2003 See comment See comment One death; but the authors did not specify which group the death was in.
Sauvage 2017
  • Serious adverse events: 2 deaths, a massive septic shock with acute pulmonary oedema and a decompensation of an insulin‐dependent diabetes.

  • 20 adverse events, including 2 discomforts.

  • No serious adverse events reported

  • 20 adverse events, including 1 hyperalgesia.

Events other than discomfort and hyperalgesia did not involve the mattresses.