Skip to main content
. 2020 Oct 21;70(6):1130–1138. doi: 10.1136/gutjnl-2020-321956

Table 3.

Diagnostic accuracy of FIT for CRC at different cut-offs

Cut-off (µg/g) Positivity (%) NNS Sensitivity (%) Specificity (%) PPV (%) NPV (%) TP FN FP TN
2 37.2 11.5 97.0 (94.5 to 98.5) 64.9 (63.9 to 65.8) 8.7 (7.8 to 9.7) 99.8 (99.7 to 99.9) 319 10 3336 6157
10 19.0 6.2 90.9 (87.2 to 93.8) 83.5 (82.8 to 84.3) 16.1 (14.4 to 17.8) 99.6 (99.5 to 99.7) 299 30 1563 7930
150 7.6 3.2 70.8 (65.6 to 75.7) 94.6 (94.1 to 95.0) 31.1 (27.8 to 34.6) 98.9 (98.7 to 99.1) 233 96 516 8977
<2 62.8 616.7 3 (1.5 to 5.5) 35.1 (34.2 to 36.1) 0.2 (0.1 to 0.3) 91.3 (90.3 to 92.2) 10 319 6157 3336

95% CIs within brackets.

CRC, colorectal cancer; FIT, faecal immunochemical test; FN, false negatives; FP, false positives; NNS, number needed to scope; NPV, negative predictive value; PPV, positive predictive value; TN, true negatives; TP, true positives.