(Color online) White noise was presented through a head-shaped, custom mouth simulator: (1) with a “listener” microphone placed at distances of 3 and 6 ft to measure acoustic attenuation relative to the no mask condition, and (2) while rotating it in 15 degree increments with the “listener” microphone placed at a fixed distance of 6 ft.