Skip to main content
. 2021 Apr 30;2021:6649970. doi: 10.1155/2021/6649970

Table 7.

Sensitivity (Se) and precision (P+) of the improved ResNet-18 model, in comparison with state-of-the-art models, for AAMI heartbeat classes V and S.

Model (ensemble learning is omitted from this comparison as there are neither sensitivity nor precision data presented for it in [11]) AAMI heartbeat class V AAMI heartbeat class S
Se (%) P+ (%) Se (%) P+ (%)
BbNNs [18] 86.60 93.30 50.60 67.90
End-to-end DNN [15] 93.70 Not provided 77.30 Not provided
1D-CNN [10] 93.90 90.60 60.30 63.50
Improved ResNet-18 (the proposed model) 93.83 97.44 76.45 83.87