Skip to main content
. 2021 May 3;9(5):23259671211001773. doi: 10.1177/23259671211001773

Table 1.

Characteristics of the Included Studiesa

Lead Author (Year) No. of AA-DCF Age, y, mean ± SD Male, % Neer Type Surgical Construct Union Rate, % Complications Reoperations
Blake (2017)4 17 41.0 ± 19.0 35 II Arthrex TightRope CC fixation with modified fracture site cerclage 82 3 nonunions, 1 deep infection, 1 adhesive capsulitis, 1 symptomatic cerclage suture 1 I&D, 1 suture debridement/ROH
Checchia (2008)7 7 46.3 ± 10.8 57 II (n = 3), V (n = 4) Double Arthrex No. 5 FiberWire clavicular subcoracoid cerclage 100 1 superficial infection, 1 adhesive capsulitis
Flinkkilä (2015)9 21 39.0 ± 14.0 95 II Arthrex TightRope CC fixation vs hooked plate 95 1 nonunion, 1 hardware failure, 1 infection, 1 sinus formation 1 revision fixation, 1 I&D, 1 excision of sinus tract
Kraus (2015)12 20 38.3 ± 7.3 65 II Arthrex TightRope CC fixation with fracture site cerclage 95 1 nonunion, 1 hardware failure, 1 symptomatic implant, 6 CC ossifications 1 revision fixation, 1 ROH
Kuner (2019)13 20 45.0 ± 12.0 70 II Arthrex TightRope or DogBone CC fixation 70 6 nonunions, 1 wound complication, 2 adhesive capsulitis, 2 symptomatic implants 2 nonunion revisions, 1 scar revision, 2 ROH
Lim (2019)14 5 51.6 ± 19.8 20 IIb Arthrex DogBone CC fixation NR 5 CCBRCCT, 1 superficial infection, 2 hardware failures, 1 button migration, 1 CC ossification 2 revision fixations, 1 I&D
Loriaut (2015)15 21 33.0 ± 12.3 67 IIb Arthrex TightRope CC fixation 95 1 hardware failure with nonunion, 1 symptomatic implant, 1 adhesive capsulitis, 2 CC ossifications None
Lu (2010)16 7 51.0 ± 17.0 57 IIb Arthrex TightRope CC fixation with modified fracture site cerclage fixation 100 None None
Mochizuki (2019)17 23 34.3 ± 9.5 NR IIb Zimmer ZipTight + K-wire 100 NR None
Motta (2014)19 14 32.0 ± 5.8 100 IIa (n = 2), IIb (n = 10), V (n = 2) Arthrex TightRope CC fixation 100 1 superficial infection, 3 SCCB, 2 button migrations, 2 CC ossifications None
Pujol (2008)24 4 35.0 ± 5.0 75 NR Arthrex TightRope CC fixation 100 None None
Sautet (2018)27 14 34.6 ± 6.8 71 IIb Subcoracoid suture, Arthrex DogBone clavicular cortical button 100 4 symptomatic implants 2 ROH
Takase (2012)31 7 41.9 ± 0.50 100 II Smith & Nephew Endobutton (coracoid side) with spike washer and screw (clavicle side) fixation with Dacron (Smith & Nephew) artificial ligament 100 None None
Takase (2019)32 18 43.5 ± 6.8 90 II Smith & Nephew Endobutton (coracoid side) with spike washer and screw (clavicle side) fixation with Dacron artificial ligament 100 None None
Xiong (2018)34 28 41.9 ± 13.5 59 IIa (n = 12), IIb (n = 16) Arthroscopic Smith & Nephew double Endobutton vs hook plate vs LCP 96 1 nonunion 1 nonunion revision

aAA-DCF, arthroscopically assisted distal clavicle fractures; CC, coracoclavicular; CCBRCCT, cortical coracoid breach requiring conversion of construct or technique; I&D, irrigation and debridement; K-wire, Kirschner wire; LCP, locking compression plate; NR, not reported; ROH, removal of hardware; SCCB, salvageable cortical coracoid breach.