The influences of applied voltage and inlet air velocity on ΔCozone in Case-4.

Applied voltage: 6.5 kV Applied voltage: 8.5 kV
Inlet air velocity: 1 m/s 8.0 ppb 14.0 ppb
Inlet air velocity: 3 m/s 2.7 ppb 4.7 ppb
Inlet air velocity: 5 m/s 1.6 ppb 2.8 ppb